Peerzada Waris Ahmad , Brahamjeet Singh
In India, Multi-storied structures built are deficient of land and have to carry maximum load. Earthquake could be a circumstance which might result in the failure of the structure. Buildings are to be created so that they are safe to live in and the structure before failure should possess ductile property. To prevent structures from failing and from serious damages the structures before construction should be analyzed for its seismic performance along with support reactions and wind calculations both are to be included in the design of an earthquake resistant structure. The primary objective of present study is to make earthquake resistant structure by retrofitting its columns and the process is known as column jacketing. The retrofitted structure is analyzed in the E-tabs software. For this purpose, a retrofitted G+5residentialbuilding is considered. Calculations are done for an earthquake in seismic zone V. To guarantee the safety of the structure all the forces acting on the structure including the lateral loads due to wind and seismic excitations are considered. Because of the jacketing the column strength and the overall stability of the structure will increase. By using IS Code (IS 15988-2013), the jacketing will be done in E-tabs software. After the jacketing the various responses including bending moment, shear force of existing building will be studied under various loads for an earthquake in seismic zone V.
[1] IS 1893 (2016): Seismic evaluation and Strengthening of existing reinforced concrete building-guidelines. Bureau of Indian Standards, New Delhi, page 1-27
[2]. Methods of seismic retrofitting by using e-tabs software. International Journal of Civil Engineering and Technology, Volume 8, Issue: 5, May 2017, pp. 94–99.
[3]. Retrofitting of Columns of an Existing Building by RC, FRP and SFRC Jacketing Techniques, (IOSR-JMCE) e-ISSN: 2278-1684, p-ISSN: 2320–334X https://www.researchgate.net/publication/305625198
[4]. Design and Modelling of Concrete Jacketing after Analysis of an Existing RC Building using ETABS, Volume 07, Issue: 08, Aug 2020 https://www.irjet.net
[5]. Comparative study on the seismic performance assessment of existing building with and without retrofit strategies.International Journal of Advanced Structural Engineering, Springer https://www.researchgate.net/publication/329127335
[6]. IS 1392 (2016):Ductile Detailing of Reinforced Concrete Structure Subjected to Seismic forces. Bureau of Indian standards, New Delhi, page 1-18
[7]. IS 456 (2000): Indian code of practice for plain and reinforced concrete. Bureau of Indian Standards, New Delhi.
M.Tech Scholar, Department of Civil Engineering, RIMT University, Punjab, India
No. of Downloads: 47 | No. of Views: 913